GEF Assay – A Transcreener GDP Assay Application

Transcreener GDP assay directly measures GDP produced by GTPases when GEF proteins stimulate the enzyme. These GDP measurements allow researchers to effectively determine the GEF activity. The assay provides a powerful tool to screen compound libraries for GEF modulators to help find new therapies for disease.

Active Rho GTPases stimulate cell growth and migration, sometimes triggering tumorigenesis or invasion. Rho GEFs (guanine nucleotide exchange factors) positively regulate Rho GTPases by accelerating GDP dissociation and allowing the formation of the active GTPase-GTP complex.

By accelerating GDP dissociation, the rate-limiting step of the GTPase catalytic cycle, GEFs enhance the steady state rates of GTP hydrolysis by GTPases. These changes can be detected using the Transcreener® GDP GEF Assay, which relies on a highly selective antibody and far-red fluorescent tracer to allow homogeneous detection of GDP with fluorescence readouts.

GEF Enzyme Reaction Cycle

GAP & GEF Enzyme Reaction Cycle

This assay is designed to be used with purified enzyme preparations. Transcreener assays are not validated with cell lysates, blood, serum, or other biological samples.

How Does This GEF Assay Work?

The Transcreener GEF Assay determines GEF activity by measuring increases in GDP formation as GEF proteins stimulate the GTPase. By detecting GDP output, the assay provides a universal method to assess the activity of any GDP-producing enzyme in real-time.

Transcreener GEF Assay technology uses a simple but highly effective method that consists of an antibody selective to GDP and a far-red fluorescent tracer. GDP produced in the reaction competes with the tracer changing the fluorescent properties and providing fluorescent readout.

The GEF assay is available with FP, FI, and TR-FRET. It is a simple mix-and-read format. Perform your enzyme reaction, add the detection reagent, and measure. The simplicity of the system yields robust results that also make it extremely amiable to HTS.

Direct Detection of GDP to Measure GEF Activity
Transcreener GDP GTPase Assay Schematic

A High-Throughput Assay for Rho Guanine Nucleotide Exchange Factors Based on the Transcreener GDP Assay

Download Icon

Applications

  • Measure GTPase-GEF Catalytic Activity
  • Screen Compound Libraries for GEF Modulators
  • Quantify Inhibitor Potency
  • Inhibitor Selectivity Profiling

Features

  • Direct detection of unlabeled GDP
  • Easy to use, homogenous, one-step format
  • Robust Assay Z’ > 0.7 under initial velocity conditions
  • Far-red fluorescent readouts minimize compound interference
  • A safe, non-radioactive method
  • Available in FP, FI, or TR-FRET readouts

Easy-to-Use, Mix-and-Read, HTS-Ready Assay

Run your enzyme reaction, add Transcreener reagents, and read your plates. The GEF assay is compatible with 96, 384, and 1536-well formats.

Transcreener Mix and Read Assay

Development of GEF Assays with Transcreener’s GDP Assay

GTPase Titration

Cdc42 and RhoA titration to identify a concentration that produces ~20% of the maximal signal. The data indicates 39 nM Cdc42 & 78 nM RhoA are optimal for detecting GEF-dependent stimulation of steady-state GTPase activity.

Enzyme Titration GEF Assay

Dbs (GEF) Titration

Adding Dbs to reaction containing a low concentration of RhoA and Cdc42 created a dose-dependent increase in the signal observed, suggesting that accelerating GDP dissociation increases the steady-state rate of GTPase activity. Optimal Dbs concentration was 100 nM.

Dbs Titration2

GEF Effect on Rho GTPases

Time course data showing the change in GTPase activity of Cdc42 and RhoA in the presence and absence of Dbs, as measured by changes in FP using Transcreener® GDP assay. The polarization values from the GTPase/GEF reactions were converted to GDP formed.

Change in Cdc42 Activity With and Without Dbs

Continous GEF Assay With Cdc42 and Dbs
Standard Curve GEF Assay With Cdc42 and Dbs

Assay demonstrates linearity when raw data is converted to GDP using a standard curve

Change in RhoA Activity With and Without Dbs

Continous GEF Assay With RhoA and Dbs
Standard Curve GEF Assay With RhoA and Dbs

Assay demonstrates linearity when raw data is converted to GDP using a standard curve

GEF Assay Services

Interested in moving your program forward, but don’t want to bring an assay in-house? Our scientists can help! BellBrook scientists will use their extensive biochemistry and enzymology expertise to work with you and accelerate your GTPase program (right here in Madison, Wisconsin). We can provide modulator potency profiling for GTPases, along with a variety of other GTPase enzymes, related GAPs, GEFs, and other proteins. Get accurate IC50 results fast to understand how your lead molecule interacts with other GTPases.

Lead Discovery Services Include:
  • Inhibitor Screening

    To identify or confirm activity with the target.

  • Inhibitor Potency Profiling

    Dose-response with target and/or related proteins. Fast IC50 results.

  • Residence Time Measurements

    Determination of koff using ‘jump dilution’ enzymatic assay method.

  • Mechanism of Action Studies

    Kinetic analysis to define the mode of inhibition.

Contact Us to Learn More

Please fill out the form below. We will respond quickly to get the conversation moving and learn how we can help. We keep things discrete, confidential, and professional.

Name(Required)

What’s Included

ComponentNotes
GDP AntibodyAntibody specific to the nucleotide GDP. Yours may vary depending on enzyme and buffer composition.
GDP TracerWhen displaced, changes in fluorescence can be read in an FP, FI, or TR-FRET depending on the assay format.
GTP and GDPGTP and GDP are used to create the GTP/GDP standard curve. GTP is used as a phosphate donor to start the reaction.

What You Will Need

ComponentNotes
EnzymePlease use purified enzymes for best results.
Enzyme BufferUser-supplied enzyme buffer components include enzyme, buffer, acceptor substrate, MgCl2 or MnCl2, Brij-35, and test compounds.
Assay PlatesAssay Plates Can Be Purchased Directly Through BellBrook Labs

FP - An entirely black plate with a non-binding surface is required. We suggest Corning 384-well plates Cat. #4514

FI - An entirely black plate with a non-binding surface is required. We suggest Corning 384-well plates Cat. #4514

TR-FRET - An entirely white plate with a non-binding surface is required. We suggest Corning 384-well plates Cat. #4513
Plate ReaderA multi-detection microplate reader configured to measure the output of the GDP tracer is required.
Liquid Handling DevicesUse liquid handling devices that can accurately dispense sub-microliter volumes into 384-well plates.
Ultrapure WaterSome deionized water systems are contaminated with nucleases that can degrade both nucleotide substrates and products, reducing assay performance. Careful handling and use of ultrapure water eliminates this potential problem.

GAPs & GEFs As Therapeutic Targets

GTPases control diverse cellular processes by cycling between inactive GDP- and active GTP-bound conformations. GAPs & GEFs regulate this active and inactive cycling. Rho family GTPases control cell growth, movement and gene expression and are often misregulated in cancer pathways, especially cell migration and invasion.

Rho GTPases are infrequently mutated, and their tumorigenic functions are often mediated by overexpression of GEFs. This positively regulates Rho GTPases by accelerating GDP dissociation to form the active, GTP-bound complex.

The Transcreener GDP GEF Assay is an excellent tool for researchers examining GEF for therapeutic treatments by directly measuring GDP produced in the reaction.

Resources

Find the right resources to help you get to your solution faster.

Contact Us to Learn More

Please fill out the form below. We will respond quickly to get the conversation moving and learn how we can help. We keep things discrete, confidential, and professional.

This field is for validation purposes and should be left unchanged.
Name(Required)

“Some CROs reserve their best teams for high profile customers. If you’re not right there with them you get less experienced teams… BellBrook understands enzyme kinetics, so it made that part of the project so much easier. The larger CRO didn’t seem to have the expertise we needed in this area.”

“The ADP assay is a great choice for measuring activity for any ADP-generating enzyme in both real time and endpoint formats. The universal detection system has been very useful for more challenging targets.”

“Excellent blend of simplicity & good science. Excellent technical support”

“The assay itself has good reproducibility and provides a clear readout on our enzyme activity. The most important piece, however, is the level of attention to our project and rapid turnaround time. The staff at BellBrook knows what they are doing.”

“The Transcreener AMP/GMP Assay is extremely straightforward to use and is very sensitive. In a UV-based enzyme assay I needed 1 µM enzyme to see a decent signal; however using the Transcreener AMP assay I only need 10 nM. Also, BellBrook Labs have been very helpful with the assay development. Their representative has been very willing to quickly help me get my assay up and running.”

“Through the process of developing and validating an assay for HTS applications, I generated a very nice data package of robust high quality data.”