PKR Assay – A Transcreener ADP² Assay Application

Transcreener ADP² Assay directly measures ADP produced by PKR  (Protein Kinase R or EIF2AK2). These ADP measurements allow researchers to effectively determine the activity of the PKR enzyme. The assay provides a powerful tool to screen compound libraries for PKR modulators to help find new therapies for disease.

The kit comes complete with the detection reagents required to measure activity. PKR enzyme is not included in the inhibitor screening assay kit. Please contact us for questions related to acquiring the enzyme.

This assay is designed to be used with purified enzyme preparations. Transcreener assays are not validated with cell lysates, blood, serum, or other biological samples.

Application Note: Detection of Protein Kinase R Activity with the Transcreener ADP2 Assay

This field is for validation purposes and should be left unchanged.
Name(Required)
Download Icon

How Does This PKR Assay Work?

The Transcreener PKR Assay determines PKR enzyme activity by directly measuring the ADP formed by the enzyme using the Transcreener ADP Assay. By detecting ADP output, the assay provides a universal method to assess the activity of any ADP-producing enzyme in real-time.

Transcreener PKR Assay technology uses a simple but highly effective method that consists of an antibody selective to ADP over ATP and a far-red fluorescent tracer. ADP produced in the reaction competes with the tracer changing the fluorescent properties and providing fluorescent readout.

The PKR assay is available with FP, FI, and TR-FRET. It is a simple mix-and-read format. Perform your enzyme reaction, add the detection reagent, and measure. The simplicity of the system yields robust results that also makes it extremely amiable to HTS.

Applications

  • Measure Enzymatic Activity of PKR
  • Screen Compound Libraries for PKR Modulators
  • Quantify Inhibitor Potency
  • Inhibitor Selectivity Profiling
  • Measure Drug-Target Residence Time

Features

  • Direct detection of unlabeled ADP
  • Easy to use, homogenous, one-step format
  • Robust Assay Z’ > 0.7 under initial velocity conditions
  • Far-red fluorescent readouts minimize compound interference
  • A safe, non-radioactive method
  • Available in FP, FI, or TR-FRET readouts

Easy-to-Use, Mix-and-Read, HTS-Ready Assay

Run your enzyme reaction, add Transcreener reagents, and read your plates. The PKR assay is compatible with 96, 384, and 1536-well formats.

Transcreener Mix and Read Assay

Robust Assay Yields Quality Data

Z’ measurements using optimized PKR reaction conditions indicate a robust assay. Robust data like this is vital for sizeable high throughput screens that are difficult to complete due to massive sample quantity. Z’ shown here = 0.91. Assay conditions based off eIF2α as substrate.

Z' Data for PKR

Detection of ADP Under PKR Initial Velocity (eIF2α Substrate)

The assay demonstrates linearity when raw data is converted to ADP using a standard curve. Here we use 10 µM ATP with 200 nM eukaryotic initiation factor-2α (eIF2α). Linearity is shown here under initial velocity conditions when raw data is converted to ADP formed. The enzyme buffer includes 50 mM Tris pH 7.5, 10 mM MgCl2, and 0.01% Brij. The Detection mix included 40 μg/mL ADP2 antibody, 4 nM ADP Alexa 633 tracer, and 1X Stop & Detect Buffer B in 10 μL. The PKR enzyme reaction took place for 60 minutes at room temperature. The Detection Mix was added and incubated for 60 minutes at room temperature and read with a CLARIOstar plate reader.

PKR Enzyme Titration

PKR Assay Enzyme Titration with elF2a Substrate

Linear Response

PKR Linear Response Curve with elF2a substrate

Detection of ADP Under PKR Initial Velocity (MBP Substrate)

The assay demonstrates linearity when raw data is converted to ADP using a standard curve. Here we use 10 µM ATP with 100 ug/mL Myeline Basis Protein (MBP). Linearity is shown here under initial velocity conditions when raw data is converted to ADP formed. The enzyme buffer includes 50 mM Tris pH 7.5, 10 mM MgCl2, and 0.01% Brij. The Detection mix included 40 μg/mL ADP2 antibody, 4 nM ADP Alexa 633 tracer, and 1X Stop & Detect Buffer B in 10 μL. The PKR enzyme reaction took place for 60 minutes at room temperature. The Detection Mix was added and incubated for 60 minutes at room temperature and read with a CLARIOstar plate reader.

PKR Enzyme Titration

PKR Assay Enzyme Titration with MBP Substrate

Screen for Inhibitors & Perform SAR

Transcreener Assays are designed for screening compound libraries in a high throughput format. Follow-up SAR can also be performed using the assay to determine inhibitor potency with ease. Assay conditions include 320 ng/mL PKR, 50 nM Tris, 0.01% Brig, 10 mM MgCl2, 10 μM ATP, 200 nM eIF2α . The Detection Mix consists of 1X Stop & Detect Buffer B, 40 μg/mL ADP Ab, and 4 nM 633 tracer. Assay was inhibited with Staurosporine for 30 minutes prior to the enzymatic reaction at room temperature.

Dose-Response – Staurosporine

PKR Assay Dose Response Curve in Percent Inhibition

IC50 = 0.09 µM

Three Fluorescent Readout Options

Choose the readout that is the best fit for your lab based on preference and plate reader compatibillity.

Fluorescent Intensity

FI Readout for PKR Titration

FI Detection Mix (10 μL): 1x Stop & Detect Buffer B, 40 μg/mL ADP Ab-IRDye QC1, 8 nM AlexaFluor 594 Tracer. Assay conditions based off eIF2α as substrate.

TR-FRET

PKR Assay Titration with a TR-FRET Readout

TR-FRET Detection Mix (10 μL): 1x Stop & Detect Buffer C, 8 nM ADP Ab-Tb, 1000 nM ADP HiLyte647 tracer. Assay conditions based off eIF2α substrate.

PKR Assay Services

Interested in moving your program forward, but don’t want to bring an assay in-house? Our scientists can help! BellBrook scientists will use their extensive biochemistry and enzymology expertise to work with you and accelerate your PKR program.

Lead Discovery Services Include:
  • Inhibitor Screening

    To identify or confirm activity with the target.

  • Inhibitor Potency Profiling

    Dose-response with target and/or related proteins. Fast IC50 results.

  • Residence Time Measurements

    Determination of koff using ‘jump dilution’ enzymatic assay method.

  • Mechanism of Action Studies

    Kinetic analysis to define the mode of inhibition.

Contact A Scientist About Services Today

Please fill out the form below. We will respond quickly to get the conversation moving and learn how we can help. We keep things discrete, confidential, and professional.

Name(Required)

What’s Included In The Transcreener Kit

ComponentNotes
ADP² AntibodyAntibody specific to the nucleotide ADP. Suggested ADP² antibody concentration for 10 μM ATP (in the Detection Mixture) with FP readout- 40 μg/mL, TR-FRET readout- 8 nM, and FI readout- 40 μg/mL. Yours may vary depending on enzyme and buffer composition.
ADP TracerWhen displaced, changes in fluorescence can be read in an FP, FI, or TR-FRET depending on the assay format. 
Stop & Detect BufferThe Stop & Detect Buffer components will stop enzyme reactions that require Mg2+. To ensure that the enzyme reaction is stopped completely, confirm that the EDTA concentration is at least equimolar to the magnesium ion concentration in the reaction.
ATP and ADPATP and ADP are used to create the ATP/ADP standard curve. ATP is used as a phosphate donor to start the reaction. We suggest using a starting ATP concentration of 10 μM for PKR.

Additional Materials You Will Need

ComponentNotes
Protein Kinase R (PKR) EnzymeWe have successfully used recombinant human PKR from Fisher Scientific #PV4821. A PKR concentration of 320 ng/mL was used for screening and SAR.
Enzyme Buffer50 nM  Tris (pH 7.5), 10 mM MgCl2, and 0.01% Brij-35. Enzyme Buffer components may be optimized as required.
eIF2a Substrate200 nM of eIF2a from Enzo Life Sciences #ADI-KPR-CP132-0050
MBP Substrate100 ug/mL of MBP from Sigma-Aldrich #M1891-1MG
Assay PlatesAssay Plates Can Be Purchased Directly Through BellBrook Labs

FP - An entirely black plate with a non-binding surface is required. We suggest Corning 384-well plates Cat. #4514

FI - An entirely black plate with a non-binding surface is required. We suggest Corning 384-well plates Cat. #4514

TR-FRET - An entirely white plate with a non-binding surface is required. We suggest Corning 384-well plates Cat. #4513
Plate ReaderA multi-detection microplate reader configured to measure the output of the ADP tracer is required.
Liquid Handling DevicesUse liquid handling devices that can accurately dispense sub-microliter volumes into 384-well plates. 
Ultrapure WaterSome deionized water systems are contaminated with nucleases that can degrade both nucleotide substrates and products, reducing assay performance. Careful handling and use of ultrapure water eliminates this potential problem.

The Role of PKR As a Therapeutic Target

Protein Kinase R is a serine-threonine kinase with a central role in anti-viral activity through various PKR pathways. PKR decreases viral replication via phosphorylation of eukaryotic translation initiation factor (eIF2α), preventing further mRNA translation and protein synthesis. PKR also activates antiviral interferon cytokines through activation of nuclear factor kappa-light-chain-enhancers of activated B cells (NFkB) and induces apoptosis of viral cells, limiting spread of viral infection. The role PKR plays in anti-viral pathways has made it an emerging target for antiviral therapies. (Gal-Ben-Ari et al., 2019)

The Transcreener ADP² PKR Assay is an excellent tool for researchers examining the antiviral effects of PKR.

Resources

Find the right resources to help you get to your solution faster.

Contact Us to Learn More

Please fill out the form below. We will respond quickly to get the conversation moving and learn how we can help. We keep things discrete, confidential, and professional.

This field is for validation purposes and should be left unchanged.
Name(Required)

“Some CROs reserve their best teams for high profile customers. If you’re not right there with them you get less experienced teams… BellBrook understands enzyme kinetics, so it made that part of the project so much easier. The larger CRO didn’t seem to have the expertise we needed in this area.”

“The ADP assay is a great choice for measuring activity for any ADP-generating enzyme in both real time and endpoint formats. The universal detection system has been very useful for more challenging targets.”

“Excellent blend of simplicity & good science. Excellent technical support”

“The assay itself has good reproducibility and provides a clear readout on our enzyme activity. The most important piece, however, is the level of attention to our project and rapid turnaround time. The staff at BellBrook knows what they are doing.”

“The Transcreener AMP/GMP Assay is extremely straightforward to use and is very sensitive. In a UV-based enzyme assay I needed 1 µM enzyme to see a decent signal; however using the Transcreener AMP assay I only need 10 nM. Also, BellBrook Labs have been very helpful with the assay development. Their representative has been very willing to quickly help me get my assay up and running.”

“Through the process of developing and validating an assay for HTS applications, I generated a very nice data package of robust high quality data.”